Search results for "Poly(methyl methacrylate)"

showing 10 items of 26 documents

Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.

2012

To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentCorneal StromaVision DisordersVisual AcuityComa (optics)Power vectorKeratoconusRefraction OcularCohort StudiesProsthesis ImplantationYoung AdultOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesAlpins methodAgedIntrastromal corneal ring segmentbusiness.industryCorneal TopographyProstheses and ImplantsMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologySurgeryFemalesense organsLaser TherapyCorneal ringbusinessJournal of cataract and refractive surgery
researchProduct

Femtosecond laser–assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty

2013

PURPOSE: To assess the visual and refractive outcomes of femtosecond laser-assisted implanta- tion of Ferrara-type intrastromal corneal ring segments (ICRS) in post-penetrating keratoplasty (PKP) eyes. SETTING: Instituto OftalmolFernOviedo, Spain. DESIGN: Cohort study. METHODS: Patients with previous PKP had ICRS implantation after femtosecond laser tunnel creation. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation. The power vector method was used to analyze refractive errors preoperatively and postoperatively. RESULTS: This study enrolled 32 eyes of 30 patients. The mean UDVA (Snell…

AdultMalemedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentVisual AcuitySpherical equivalentAstigmatismRefraction OcularPower vectorCorneal DiseasesCohort StudiesProsthesis ImplantationYoung AdultHigh astigmatismOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesIntrastromal corneal ring segmentbusiness.industryAstigmatismProstheses and ImplantsMiddle Agedmedicine.diseaseLaser assistedeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleSurgeryLaser Therapysense organsCorneal ringbusinessKeratoplasty PenetratingJournal of Cataract and Refractive Surgery
researchProduct

Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive viscoelastic agent.

1999

Cataract surgery and intraocular lens (IOL) implantation in pediatric eyes remain controversial. Using a viscoadaptive viscoelastic agent, we implanted a modified capsular bending ring (CBR) as well as an acrylic IOL with a sharp-optic-edge design in the capsular bag. All operated eyes demonstrated a low postoperative inflammatory reaction and a clinically well-centered IOL. The band-shaped, sharp-edged CBR facilitates the creation of a sharp, discontinuous bend in the equatorial capsule, which prevents anterior and posterior capsule opacification. Combining the viscoadaptive viscoelastic agent and the CBR enhances the safety of primary and secondary posterior chamber IOL implantation in pe…

Capsule Opacificationmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentLens Capsule CrystallineIntraocular lensBiocompatible MaterialsCataract ExtractionProsthesis ImplantationLens Implantation IntraocularOphthalmologymedicineHumansPolymethyl MethacrylateHyaluronic AcidChildPosterior capsule opacificationLenses Intraocularbusiness.industryCapsuleCataract surgeryeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeCapsular bagSurgerysense organsbusinessPediatric cataractFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Preferential solvation of poly(methyl methacrylate) and a bisphenol A diglycidyl ether by size-exclusion chromatography

2004

The preferential adsorption coefficient, lambda, of poly(methyl methacrylate), PMMA, in solutions formed by an epoxy resin in tetrahydrofuran (THF), was studied by size-exclusion chromatography (SEC). Only PMMA of lowest molar mass was preferentially solvated by epoxy but at low concentrations of epoxy in the mixture. At higher epoxy content PMMA was preferentially solvated by THF. A simultaneous and competitive solvation between the specific interactions PMMA-epoxy and the self association of epoxy at high concentrations would be the responsible of this inversion point. The more compacted coil of PMMA of higher molecular weights in solution could explain the lack of interaction of these po…

Chemical PhenomenaSize-exclusion chromatographymacromolecular substancesBiochemistryAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundPolymer chemistryPolymethyl MethacrylateBenzhydryl CompoundsMethyl methacrylateFuransBisphenol A diglycidyl etherTetrahydrofuranChromatographyMolar massChemistry PhysicalOrganic Chemistrytechnology industry and agricultureGeneral MedicineEpoxyequipment and suppliesPoly(methyl methacrylate)Molecular Weightbody regionsSolubilitychemistryvisual_artCalibrationChromatography Gelvisual_art.visual_art_mediumEpoxy CompoundsAlgorithmsJournal of Chromatography
researchProduct

A refractive free-space microoptical 4 x 4 interconnect on chip level with optical fan-out fabricated by the LIGA technique

2002

A parallel purely refractive 4/spl times/4 optical data link has been built. The design is based on pairs of crossed cylindrical microlenses. The optical module is fabricated and monolithically integrated in. polymethyl methacrylate (PMMA) by the LIGA technique.

Interconnection3D optical data storageMaterials sciencePolymethyl methacrylatebusiness.industryFan-outOptical polymersFree spaceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOptical ModuleOpticsOptoelectronicsElectrical and Electronic EngineeringbusinessLIGAIEEE Photonics Technology Letters
researchProduct

Closed foldable capsular rings

2004

A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.

Lens capsulemedicine.medical_specialtyPhacoemulsificationMaterials sciencePolymethyl methacrylatemedicine.medical_treatmentForcepsLens Capsule CrystallineCapsuleProstheses and ImplantsPhacoemulsificationAnatomyCataractSensory SystemsProsthesis ImplantationOphthalmologyPostoperative ComplicationsOphthalmologymedicineHumansPolymethyl MethacrylateSurgeryPosterior capsule opacificationJournal of Cataract and Refractive Surgery
researchProduct

Solvent for removing silicone oil from intraocular lenses: experimental study comparing various biomaterials.

2000

Abstract Purpose To evaluate the effectiveness of a perfluorocarbon—perfluorohexyloctane (PFHO)—in removing silicone oil from different intraocular lenses (IOLs) and determine whether any removal technique enhances the removal of silicone oil. Methods Six IOL materials were analyzed: standard poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, AcrySof, 2 polyHEMAs with different water contents, and a second-generation SLM-2 silicone. One or 2 μL of a highly viscous silicone oil (5700 cs) was applied to the center of each IOL optic. Perfluorohexyloctane (2 mL) was then used to remove the silicone oil by 1 of 3 techniques: immersion of the IOL in PFHO; irrigation of the sil…

Lens materialsmedicine.medical_specialtyMaterials scienceSurface Propertiesmedicine.medical_treatmentIntraocular lensBiocompatible Materialschemistry.chemical_compoundSiliconemedicineHumansPolymethyl MethacrylateSilicone OilsLenses IntraocularFluorocarbonsComputerized analysisBiomaterialAdhesivenessReproducibility of ResultsSensory SystemsSilicone oilSurgerySolventOphthalmologychemistryIntraocular lensesSolventsMethacrylatesSurgeryBiomedical engineeringJournal of cataract and refractive surgery
researchProduct

EMG-guided percutaneous placement of cement-augmented pedicle screws for osteoporotic thoracolumbar burst fractures

2017

Background: Percutaneous techniques have increasingly gained popularity in recent years. The application of technological innovation, including neuromonitoring techniques, has the potential to increase the safety and efficacy of these procedures. Methods: Thirty patients suffering from osteoporotic dorsolumbar burst fracture were prospectively enrolled in this study. The patients underwent percutaneous fenestrated pedicle screw fixation augmented with polymethylmethacrylate (PMMA) injection. A novel surgeon-dedicated neuromonitoring device was used in order to increase the safety and the accuracy of the screw insertion. A second group of 30 patients who did not undergo neuromonitoring durin…

MalePercutaneousPercutaneous techniquesPercutaneous pedicle screw fixationNeuromonitoringFracture Fixation Internal0302 clinical medicinePedicle ScrewsFracture FixationProspective StudiesPedicle screwTomographyMinimally invasive spinal surgery030222 orthopedicsCementoplastyLumbar VertebraeSettore MED/27 - NeurochirurgiaSpinal FractureBone CementsMiddle AgedX-Ray Computedmedicine.anatomical_structuresurgical procedures operativeBurst fractureSpinal FracturesFemaleHumanmusculoskeletal diseasesmedicine.medical_specialtyOsteoporotic FractureLumbar vertebraeCement augmentationThoracic VertebraePedicle Screw03 medical and health sciencesBone CementBurst fracturemedicineHumansMinimally Invasive Surgical ProceduresPolymethyl MethacrylateAgedCementbusiness.industryElectromyographyMinimally Invasive Surgical Proceduremedicine.diseaseequipment and suppliesInternalSurgeryProspective StudieThoracic vertebraeSurgeryCementoplastyNeurology (clinical)businessTomography X-Ray Computed030217 neurology & neurosurgeryOsteoporotic Fractures
researchProduct

Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism

1999

Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismRefraction OcularCataractCorneaHigh astigmatismLens Implantation IntraocularOphthalmologyHumansPolymethyl MethacrylateMedicineDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationMiddle AgedCataract surgeryequipment and suppliesmedicine.diseaseeye diseasesSensory SystemsSurgeryToric lensOphthalmologySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct